Process Control and Instrumentation MCQs with answers Page - 7

Here, you will find a collection of MCQ questions on Process Control and Instrumentation. Go through these questions to enhance your preparation for upcoming examinations and interviews.

To check the correct answer, simply click the View Answer button provided for each question.

Have your own questions to contribute? Click the button below to share your MCQs with others!

+ Add Question

A

Admin • 833.24K Points
Coach

Q. A bolometer is

  • (A) Used for the measurement of thermal radiation
  • (B) An element which senses optical input and delivers thermal output
  • (C) Both A & B
  • (D) Neither A nor B

A

Admin • 833.24K Points
Coach

Q. Which of the following is not a speed measuring instrument?

  • (A) Psychrometer
  • (B) Stroboscope
  • (C) Tachometer
  • (D) All of the above

A

Admin • 833.24K Points
Coach

Q. A stable system is the one

  • (A) For which the output response is bounded for all bounded input
  • (B) Which exhibits an unbounded response to a bounded input
  • (C) Which satisfies the conditions for a servo problem
  • (D) None of these

A

Admin • 833.24K Points
Coach

Q. Which of the following is the dynamic characteristics of an instrument?

  • (A) Reproducibility
  • (B) Sensitivity
  • (C) Dead zone
  • (D) Fidelity

A

Admin • 833.24K Points
Coach

Q. Radiation thermometer can not measure the temperature

  • (A) Inside a pressure vessel
  • (B) Of an object without coming in contact with it
  • (C) Of liquid oxygen
  • (D) Of moving objects at high temperature

A

Admin • 833.24K Points
Coach

Q. Liquid flow rate in a small channel is best measured by a/an

  • (A) Weir
  • (B) Pitot tube
  • (C) Vane meter
  • (D) Venturimeter

A

Admin • 833.24K Points
Coach

Q. High temperature of around 2000°C of incandescent gas mantles is measured by a/an

  • (A) Specially designed thermocouple
  • (B) Optical pyrometer
  • (C) Radiation pyrometer
  • (D) None of these

A

Admin • 833.24K Points
Coach

Q. Zirconia probe is used for the continuous measurment of __________ flue gases going out of the furnace.

  • (A) Oxygen in
  • (B) Carbon dioxide in
  • (C) Carbon monoxide in
  • (D) Temperature of

A

Admin • 833.24K Points
Coach

Q. Which of the following filled system expansion thermometer has the capability to measure the lowest temperature?

  • (A) Mercury in glass thermometer
  • (B) Mercury in steel thermometer
  • (C) Alcohol in glass thermometer
  • (D) Fused metal (Na or K) in steel thermometer

A

Admin • 833.24K Points
Coach

Q. A control system is unstable, if the open loop frequency response exhibits an amplitude ratio exceeding unity at the crossover frequency. This is __________ criterion.

  • (A) Bode stability
  • (B) Nyquist
  • (C) Routh stability
  • (D) None of these

Add MCQ in this Category

If you want to share an MCQ question in this category, it's a great idea! It will be helpful for many other students using this website.

Share Your MCQ