Power Electronics MCQs with answers Page - 17

Here, you will find a collection of MCQ questions on Power Electronics. Go through these questions to enhance your preparation for upcoming examinations and interviews.

To check the correct answer, simply click the View Answer button provided for each question.

Have your own questions to contribute? Click the button below to share your MCQs with others!

+ Add Question

A

Admin • 828.03K Points
Coach

Q. A cycloconverter is a:

  • (A) Frequency changer from higher to lower frequency with one-state conversion
  • (B) Frequency changer from higher to lower frequency with two-stage conversion
  • (C) Frequency changer from lower to higher frequency with one-stage conversion
  • (D) Either a or c

A

Admin • 828.03K Points
Coach

Q. IGT stands for

  • (A) Insulated gate bipolar transistor
  • (B) Insulated gate bidirectional transistor
  • (C) Inductive gate bipolar transistor
  • (D) Inductive gate bidirectional transistor

A

Admin • 828.03K Points
Coach

Q. Number of PN junction in an SCR is

  • (A) Two
  • (B) Three
  • (C) Four
  • (D) Five

A

Admin • 828.03K Points
Coach

Q. In a silicon controlled rectifier, the load is connected

  • (A) Across anode
  • (B) In series with anode
  • (C) Across cathode
  • (D) In series with cathode

A

Admin • 828.03K Points
Coach

Q. For mercury arc rectifiers, the anode is usually made of

  • (A) Aluminium
  • (B) Copper
  • (C) Tungsten
  • (D) Graphite.

A

Admin • 828.03K Points
Coach

Q. In a phase controlled 3 phase ac voltage controller, the harmonic present is

  • (A) 2
  • (B) 3
  • (C) 5
  • (D) 7

A

Admin • 828.03K Points
Coach

Q. The maximum firing angle in the half wave controlled regulator is

  • (A) 180 degree
  • (B) 190 degree
  • (C) 200 degree
  • (D) 210 degree

A

Admin • 828.03K Points
Coach

Q. The on - state voltage drop of IGBT consists of

  • (A) Drop across the collector junction
  • (B) Drop across the drift region
  • (C) Drop across MOSFET portion
  • (D) All of these

A

Admin • 828.03K Points
Coach

Q. To detect an over - current fault condition, the most reliable method is to connect a

  • (A) Current sensor across IGBT
  • (B) Voltage sensor across IGBT
  • (C) Current sensor in series with IGBT
  • (D) Voltage sensor in series with IGBT

A

Admin • 828.03K Points
Coach

Q. The IGBT resulted in higher switching speed and lower energy losses. It can be used for

  • (A) Uninterruptible power supplies
  • (B) Induction heating system
  • (C) Constant voltage and frequency power supplies
  • (D) All of these

Add MCQ in this Category

If you want to share an MCQ question in this category, it's a great idea! It will be helpful for many other students using this website.

Share Your MCQ